USER MANUAL
2 www.CookingPerformanceGroup.com
SAFETY PRECAUTIONS
CAUTION: Potential hazard or unsafe practice could result in minor or moderate injury or product or property
damage.
NOTICE:
• Local codes regarding installation vary greatly from one area to another. The National Fire Protection
Association, Inc., states in its NFPA96 latest edition that local codes are “Authority Having Jurisdiction” when it
comes to requirement for installation of equipment. Therefore, installation should comply with all local codes.
• This product is inte
nded
for commercial use only. Not for residential use.
WARNING:
•
• Improper installation, adjustment, alteration, service or maintenance could lead to property damage, injury or
death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing
CPG equipment. This manual must be retained for future reference.
• Instructions must be posted in a prominent location. All safety precautions must be taken in the event the user
smells gas. Safety information can be obtained from your local gas supplier.
•
An authorized service agency should handle all maintenance and repair. Prior to conducting any maintenance
or repair work contact your authorized service representative.
GAS PRESSURE:
piping system during any pressure testing of that system at test pressures in excess of ½ PSI (3.45 kPa). The
during any pressure testing of the gas supply piping system at test pressures equal to or less than
½ PSI (3.45 kPa).
SERIAL PLATE
NOTE: The serial plate is located
on the side of the unit.
Made in China
Item # 351CLCPG15
Model # CBL15
LAVA BRIQUETTE CHARBROILER 15"
Total BTU: 40,000
Gas Type: Natural gas
Manifold Pressure: 6" WC
Orifice Size: # 36
CLEARANCE REQUIREMENTS:
Combustible Sides: 6”
Combustible Back: 6”
Serial # 1101000001
Conforms to ANSI STD Z83.11-2016 and certified to CSA 1.8 STD-2016
Conforms to NSF / ANSI STD. 4
Lancaster, Pennsylvania
• Equipment must be installed by a certified technician. Improper installation, adjustment,
alteration, service, or maintenance of this equipment may cause property damage or
personal injury and voids warranty.
• Carefully read and follow the installation and owner's manual prior to equipment installation or use.
• Properly attach the legs provided before appliance is permanently installed and before use.
• Use only on non-combustible countertops and away from any combustible material.
Made in China
Item # 351S60G24N
Model # S60-G24-N
60” GAS RANGE
Total BTU: 30,000
Gas Type: Natural Gas
Manifold Pressure: 4” WC
CLEARANCE REQUIREMENTS:
Combustible Sides: 6”
Serial # 1010101010101
Conforms to NSF / ANSI STD. 4
Intertek