CPI Canada Inc. Installation 2
CHAPTER 2
INSTALLATION
CONTENTS:
2.1.0
INTRODUCTION ...................................................................................................................................... 2-2
2.2.0 UNPACKING ............................................................................................................................................ 2-2
2.3.0 REMOVING THE GENERATOR COVER ................................................................................................. 2-2
2.4.0 MAJOR COMPONENT LAYOUT .............................................................................................................. 2-3
2.5.0 EQUIPMENT PLACEMENT ..................................................................................................................... 2-3
2.5.1 Main Cabinet ......................................................................................................................................... 2-3
2.5.2 Control Console .................................................................................................................................... 2-3
2.5.3 Anchoring the Generator to the Floor ................................................................................................... 2-5
2.6.0 WIRING TO THE GENERATOR ............................................................................................................... 2-5
2.6.1 Control Console .................................................................................................................................... 2-6
2.6.2 Hand Switch (Optional) ......................................................................................................................... 2-9
2.6.3 X-ray Tube Stator Cable ..................................................................................................................... 2-10
2.6.4 Checking the Connection of the X-ray Tube Stator Cable .................................................................. 2-12
2.6.5 Power Line Mains................................................................................................................................ 2-12
2.6.6 High Voltage Cables ........................................................................................................................... 2-15
2.6.7 X-Ray Tube Housing Ground .............................................................................................................. 2-17
2.6.8 Room Equipment ................................................................................................................................ 2-17
2.6.9 Emergency Power Off / Power Distribution Relay .............................................................................. 2-17
2.6.10 Safety Interlocks.................................................................................................................................. 2-17
2.7.0 LOW-SPEED STARTER TUBE COMPATIBILITY .................................................................................. 2-17
2.7.1 Setting 120 / 240 VAC Boost Voltage ................................................................................................. 2-18
2.8.0 PROGRAMMING THE DUAL-SPEED STARTER .................................................................................. 2-18
2.8.1 EPROM type / dual-speed starter - applies only to DSS Board #728877-06. .................................... 2-19
2.8.2 Tube type setting on DIP switch SW1 for DSS Boards #728877-06 and #903132-02 ....................... 2-20
2.8.3 Programming DIP switch SW3 for DSS Board #903132-xx .............................................................. 2-23
2.8.4 Inspecting DIP switch SW8 setting for DSS Board #903132-xx ......................................................... 2-26
2.8.5 Configuring dual-speed starter 901297-15 / 901298-15 ..................................................................... 2-27
2.9.0 GENERATOR CONTROL BOARD DIP SWITCH SETTINGS ................................................................ 2-28
2.10.0 INITIAL RUN-UP ..................................................................................................................................... 2-28
2.10.1 Auxiliary Transformer Line Voltage Tap Selection .............................................................................. 2-28
2.10.2 Initial Voltage Measurements .............................................................................................................. 2-30
2.11.0 TUBE MA AUTO CALIBRATION ............................................................................................................. 2-31
2.12.0 FINAL CHECKS ...................................................................................................................................... 2-31
Use and disclosure is subject to the restrictions on the title page of this CPI document.
CMP 200
X-Ray Generator Service Manual Ch # 901476-02 Rev. P Page 2-1