[Function No. 3–sds] Speed
Selection
This will take you into the
Program Mode again
“0” is
initially
displayed
This saves the speed
selection
2.3.2 Programming the Speed Selection
The last step for initial setup programming is selecting the speed for the respective application.
Follow the flowchart shown in Figure 2.3.2 below.
Fig. 2.3.2: Speed selection flowchart
Press the up
key until s8s is
displayed
Press the
Key once
FUNC
Press the
Key once
FUNC
S8S
Choose the Speed Selection for your Application.
2 Speed - Leave “0” as is. Do not enter any value.
2 Step Infinitely Variable - Press the key once.
“1” is displayed.
3 Speed - Press the key twice. “2” is displayed.
3 Step Infinitely Variable - Press the key three times.
“3” is displayed.
Currently you should
be in the
User Level
* The drive has now been programmed for its push button speed command. According to your
new selection, other related drive parameters have also changed automatically for quick
programming. See Table 2.3.2 for a list of parameters that have automatically changed.