Model: ANKA 300
Version: EN 1.00.0922
When the buttons in the Water Menu are active, they will appear in
"green” color, while inactive, they will appear as "white”. The
booster is not active when the system is first turned on. In order to
be able to use the water system in ANKA300, the booster is activated
after the system is turned on, if the system is completely turned off
and opened or reset, the booster will become passive again, in which
case it is necessary to reactivate the booster.
After the booster is activated, even if all the taps are closed, the
booster can continue to work for a while, this is due to the balancing
of the pressure in the pipe in the water system. This will take a little
longer if the boiler tank is empty. After the booster is activated, when
any faucet connected to the caravan is opened, water will
automatically start flowing. When the dirty water tank is full, the
booster will automatically turn off in order to prevent overflow. In
this way, any overflow situation that may arise from the ANKA300
installation is prevented.
When the dirty water tank reaches the level of 75%, the warning in
the picture below appears at the top of the water page, indicating
that the tank is full and that the booster will stop when the tank
level reaches 100%. When the dirty water tank reaches 100% full,
the booster will shut down. As shown in the image, there is
information about clean water on the left side of the screen, and
information about dirty water on the right. the water tank must be
emptied properly by opening the discharge valve in the tanks.
As shown in the image, there is information about clean water on
the left side of the screen, and information about dirty water on the
right.
There are two buttons in the middle of the screen. The button at the
top provides "Frost Protection” and the button at the bottom
provides the "Booster” control.
In winter, the frost protection system must be active at
temperatures of 4°C and below. Otherwise, if the tank is full, the
water in the tank will freeze and increase in volume, and the tank or
the plumbing system may be damaged depending on the increased
water volume. Being half full of the tank can prevent damage caused
by freezing, but if the water freezes, the system will become
unusable. In cases of freezing, the booster should be turned off.
If ANKA300 is not going to be used, it is recommended that the tanks
be completely emptied and parked in winter, otherwise, may be
damaged by freezing. CRAWLER company is not responsible for