12
· SLA – Service liter alarm (Water lter maintenance)
To change the Service liter alarm, follow the steps below:
1. Enter the service programming and browse through the menu (see previous instructions).
2. When [SLA] is shown on the display, enter by pressing K5.
3. Select with K1 and K2 the Service lter alarm value. The counter can be adjusted in steps of
10L = [001]: From [000] = 0L = Disabled, to [999] = 9990L.
4. Accept and save setting by pressing K5. You are back in the service programming menu.
SERVICE PROGRAMMING
· ScA – Service coee alarm (Maintenance)
To change Service coee alarm, follow the steps below:
1. Enter the service programming and browse through the menu (see previous instructions).
2. When [ScA] is shown on the display, enter by pressing K5.
3. Select with K1 and K2 the Service coee alarm value. The counter can be adjusted in steps of
1000coees = [001]: From [000] = 0coees = Disabled, to [999] = 999000coees.
4. Accept and save setting by pressing K5. You are back in the service programming menu.
· tU – Temperature units
To change the Temperature units, follow the steps below:
1. Enter the service programming and browse through the menu (see previous instructions).
2. When [tU] is shown on the display, enter by pressing K5.
3. Select with K1 and K2 the Temperature units between: [c] Celsius; [F] Fahrenheit.
4. Accept and save setting by pressing K5. You are back in the service programming menu.
· SkP – Ski - Skd – PID parameters kP, Ki & kd
To change the PID factors value, follow the steps below:
1. Enter the service programming and browse through the menu (see previous instructions).
2. When [SkP], [Ski] or [Skd] is shown on the display, enter by pressing K5.
3. Select with K1 and K2 the selected PID parameter value.
4. Accept and save setting by pressing K5. You are back in the service programming menu.