EasyManua.ls Logo

Crem EX3 MINI 1GR - Service Programming; Stand-By [Off] Status; Factory Preset; Service Menu - Access

Default Icon
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
· Stand-by [oFF] status
To put the machine on electronic Stand-by mode [oFF] from home screen, press K5 and then K3
at the same time. Message [oFF] is shown on the display.
On this mode, the heating element will remain disconnected.
To exit from the Stand-by mode, just press any button (K1 – K2 – K3 – K4) to come back to the
home screen.
· Service menu - Settings summary chart
SERVICE PROGRAMMING
Setting Description
[toU]
Boiler lling time-out
[cLE]
Cleaning program cycles
[Prd]
Dose programming
[SEn]
Level probe sensitivity
[PiF]*
Preinfusion (electronic)
[tEA]*
Automatic tea valve
[Eco]*
Eco mode functions
[tEc]
Eco mode boiler temperature
[SLA]*
Service liter alarm (Filter maintenance)
Setting Description
[ScA]*
Service coee alarm (maintenance)
[tU ]
Temperature units
[SkP]
‘kP’ PID parameter
[Ski]
‘kI’ PID parameter
[Skd]
‘kD’ PID parameter
[Sb ]
PID band parameter
[SE ]
Display temperature oset
[AUt]*
Auto On/O
* Disabled by default after PCB factory preset
· Factory preset
To restore the machine to factory default programming settings, follow the steps below:
1. Turn the machine o at the main power switch.
2. Press and hold K1+K3+K5 simultaneously while turning the main power switch back on. The
display will show [PrS] and all previously customized settings will be erased and replaced with
the factory settings.
3. Cycle the machine o and on once more at the main power switch to remove the message.
· Service menu - Access
To access the service programming settings, follow the steps below:
1. Put the machine on Stand-by mode [oFF] (see previous instructions).
2. When [oFF] is shown on the display, hold K5 for 15 seconds, until [toU] (1st menu setting) is
shown on the display.
3. Browse through the menu by pressing K1 & K2.
4. Access to each setting by pressing K5. The adjustable parameter will ash. Accept and save by
pressing K5 again.
5. To exit from the menu, browse to [ESc] (Escape) and press K5 to come back to [oFF] mode.