7
· All versions
1. To remove the porta-lter, use
a straight-blade screwdriver to
release the shower by prying
down with medium force.
4. Remove the lter basket(A),
then place the new gasket
and shower(B) into the porta-
lter(C).
2. Remove the shower and
gasket.
5. Preheat the gasket to soften the rubber. A - heat the gasket
for 15 seconds using the water from the hot water outlet, or
B - place the gasket, shower, and porta-lter in hot water for 30
seconds.
3. Remove and discard the old
gasket. Insert the new gasket
(chamfer and EXPOBAR logo
facing up) into the shower.
15s
30s
99
O
C
> 65
O
C
A
A
B B
C
WARNING!
The water from the water tap is very hot! Handle with care to prevent scalding or burns.