Ensure Priming of water system is complete before starting this step.
Notice: Hot water will not be dispensed by the cooler until the Energy Saving
Switch has been activated, located behind and at top of bottle access door.
Turn on the Energy Saving Switch ( color).RED
- To disable the heating function (Hot Water), turn off the Energy Saving Switch
(Figure 9).
DO NOT draw water from the cooler for about 30 minutes to let the water cool
or heat.
Optimum water temperatures will be reached after several hours of operation.
DISPENSING WATER
The SmartFlo SF-1 Water Cartridge has been tested and sanitized prior to packaging. During transit dust
and odors may accumulate in the water tanks and lines. Dispense and dispose of at least 1 quart (1 Liter) of
water prior to drinking any water.
Cold Water Dispense
The temperature control of the cold water is preset to dispense water between
39.2-50°F (4 to 10°C)
Optimum cold water temperatures will be reached after several hours of
operation. During this time the compressor could run continuously. This is
normal. (Figure 10)
1. Position bottle, glass or other container below water outlet
2. Depress (push downwards) cold water lever to start cold water flow
3. Release cold water lever once desired fill level is achieved
Hot Water Dispense
The temperature control of the hot water is preset to dispense water between 168.8-197.6°F (76 to 92°C)
CAUTION
This unit dispenses water at temperatures that can cause severe burns.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Activate Heating Functions
Provide Electricity
Ensure that the available power supply matches the cooler’s voltage specifications indicated on the
nameplate label (located at the rear of unit).
Plug power supply cord into receptacle.
Please ensure that cooler is set up so as access to the power outlet and plug is unobstructed.
NOTE: DO NOT turn on the Energy Saving Switch yet. Proceed to the “Prime Water System” section.
NOTE: To provide additional protection from the risk of shock, this unit MUST be connected to a ground
fault circuit interrupter (GFCI) outlet at all times. Use of an extension cord will void any warranties.
Prime Water System (Required during initial setup and after replacement of SmartFlo SF-1
Water Cartridge)
Depress the and water levers to fill their respective tanks.Cold Hot
When water begins to flow from both faucets, the tanks have been filled (approx. 1 minute per tank).
Figure 10
Figure 9