Page #15 background imageLoading...
Page #15 background image
DS 400 Side 14 of 36
8 Modbus Holding Register
8.1 Basic Values Register
Modbus
Register
Modbus
Address
No.of
Byte
Data
Type
Description
Default
Setting
Read
Write
Comment
1
0
4
Dword
Serial Number
0
R
3
2
8
String
HostName
0
R
7
6
4
Dword
HardwareVersion
0
R
sprintf(str,"%u.%02u",hw>>1
6,hw&0xffff);
9
8
4
Dword
Softwareversion
0
R
sprintf(str,"%u.%02u",sw>>1
6,sw&0xffff);
11
10
8
Byte(6)
MAC Adress
0
R
Upper 2 bytes are zero
15
14
4
Dword
Calibration Date
0
R
Unix Time
17
16
4
Dword
Betriebsstundenz
ähler
0
R
Wert in Sekunden
19
18
4
Dword
Uhrzeit
0
R
Unix Time
21
20
16
String
Brand Name
0
R
29
28
2
Word
Modbus ID
0
R
Modbus ID
30
29
2
Word
free
0
R
free
31
30
4
Dword
MbRTU Rx
Packets OK
0
R
valid RTU telegrams
received
33
32
4
Dword
MbRTU Tx
Packets
0
R
RTU telegrams transmitted
35
34
4
Dword
MbRTU CRC
Errors
0
R
CRC Errors
37
36
4
Dword
MbRtu Parity
Errors
0
R
Parity Errors