Softener-Cleer Settings
NOTE! This table is for reference purposes and should be used as a starting point. You can reduce salt dosages
based on historical operating conditions and applications.
Unit
0–3 ppm of Iron 4–6 ppm of Iron 7–10 ppm of Iron
Salt
Dosage, lb
Reserve
Capacity
Salt
Dosage, lb
Reserve
Capacity
Salt
Dosage, lb
Reserve
Capacity
9" 8
30%
13
40%
15
50%
10" 12 19 23
12" 16 25 30
14" 24 38 45
NOTE! Change the salt dosage using the HE Controller: ADV. SETUP > REGEN SETUP > SALT DOSAGE.
Change the reserve capacity using the HE Controller: ADV. SETUP > REGEN SETUP > RESERVE CAPACITY.
Regeneration Frequency
NOTE! Change the REGEN INTERVAL (Time Clock Backup) using the HE Controller: ADV. SETUP >
REGENTRIGGER > REGEN INTERVAL
Setting Alarm to Refill Mineral Reactivator
.
Unit Ounces/Regeneration Will Last X Regenerations
Container Change
Frequency (days)
9" 0.5 64 192
10" 0.75 42 126
12" 1 32 96
14" 1.5 21 63
NOTE! Table 25 is based on 32 ounce container of Mineral Reactivator and regenerating every third day.
Set the Mineral Reactivator Alarm (External Filter Alarm) using the HE Controller: ACCESSORIES > EXT. FILTER.
Example