#&'0*385*7*53275303,.(
.2!> .2! 385*7*5"7&786
High Low Off
High Open Off
Open Low Off
Open Open Off
Low High On
Low Low On
Low Open On
High High On
Open High On

#: Fuses and Wires
Regulations may require that the Model 803 be
fused. If installing a fuse, use a 10A fuse wired with
1.5mm or equivalent wire. The voltage drop across the fuse,
its holder, and connectors must be less than 1% of the
nominal system voltage.
Discharge Adjustments
Table 3 lists the voltages per cell under load that correspond
to an empty indication on the gauge (lockout point).
#&'0*.6(-&5,*)/8671*27"*77.2,6
"*77.2,$307*00&7147<
K 1.57
L 1.63
M 1.68
N 1.73 (factory setting)
O 1.78
P 1.82
Q 1.84
R 1.86
S 1.89
T 1.91
U 1.93