PROGRAMMING GUIDE PG11
$"'&130(3"..*/((6*%&ø "
Mechanical Thermostat
The mechanical thermostat has an adjustment screw used to set the temperature. The factory default setting is
200°F (93°C). When operating the brewer at higher elevations, reduce the operating temperature by 2°F for each
1000 feet of elevation above 4000 feet (1200 m).
1 Unplug the brewer power cord.
2 Remove the top cover.
3 Locate the thermostat, attached to a bracket near the back of the compartment.
4 6TJOHBnBUCMBEFTDSFXESJWFSUVSOUIFBEKVTUNFOUTDSFXPOUPQPGUIFUIFSNPTUBUDPVOUFSDMPDLXJTFUP
MPXFSUIFUFNQFSBUVSFPGBUVSOPOUIFTDSFXMPXFSTUIFUFNQFSBUVSFBQQSPYJNBUFMZ¡'¡$
When the screw is turned all the way clockwise, the thermostat is set to 200°F.
5 Replace the back cover and reconnect power.
6 If the brew temperature of the water is too cool, readjust following the above steps, keeping in mind that
too high a temperature setting at higher altitudes may cause the water in the tank to boil.