Pre-Infusion (Factory set to OFF)
to Select. Display will now show Select Button. Select desired Brew button. Current setting in seconds is displayed < to
decrease or select > to increase (range from OFF to 10 through 60 seconds),
If Pre-infusion is selected (ON), Cold Brew Lock is set to Delta 1 within 5ºF of set point and Cold Brew Lock and Pulse Brew
dissappears from the list of program selections.
to Select, Shows total gallons and total brew cycles on the unit. Not resettable.
Cold Brew Lock . . . (Factory set to OFF)
to select, < > to select desired setting (CBL 5, 15 or OFF),
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The first
setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set point for the Ready to
Brew message, however it will brew at any temperature.
Then < for Yes, > for No.
Brewer factory defaults are then reset.
Service Call (Phone number Factory set to [800] 995-0417)
to display number and change number or < to move place and EX to exit when complete This number will be displayed
during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1-2-3-4)
to display number and change number, (the number can be change 1 to 4) or < to move place and ex to exit when com-
Banner Name (Factory set to WILBUR CURTIS)
to display letters and change letters or < to move place and EX to exit when complete
This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks disables Banner
Name. If programmed, Banner Name is displayed every 5 sec. on and off.
P-Maintenance (Factory set to OFF)
to Select, Set gallons brewed to indicate P-Maintenance. Press < > to adjust from Off to 3000 gallons. Press
Beeper On/Off (Factory set to ON)
to display ON or OFF. Pressing either < > toggles between on and off.
Pulse Brew (Factory set to OFF)
Display will now show Select Button. Select desired Brew button to program. The next screen will promt you to
to select OFF or one of four pulse patterns (A to D) .
Guidelines for Pulse Brew:
This feature allows tuning of the coffee flavor. This option should only be used with the standard Gray or Purple AFS sprayheads. The
pot level should always be set first with this option OFF.
Depending on your grind profile and water conditions, the three Pulse Brew options help “tune” or change the coffee flavor. Filter
Pack type coffees typically extract better with the A and B pulse setting. Decaffeinated coffees typically extract better with the B
pulse setting. High-Yield coffees typically extract better with the C pulse setting. Of course, any of the A, B or C settings may be used
to suit your taste profile.
If Pulse Brew is selected (ON), Cold Brew Lock is set to Delta 1 within 5ºF of set point. Cold Brew Lock and Pre-infusion
disappears from the list of program selections.
When Pulse Brew is ON, disappears from the list of program selections.
Model Select – This Menu Feature Appears on
to select Airpot Brewer. Screen choices are: ALPHA-1, ALPHA-2, ALPHA-3/4/5, Airpot Brewer and Thermo-
> to select Airpot Brewer. Screen choices are: ALPHA-1, ALPHA-2, ALPHA-3/4/5, Airpot Brewer and Thermo->
to set. The control will reset itself when a new model is selected.
to select, exits program mode and returns unit to operation. Pressing
returns you to Brew By Volume.