1.0 Technical Specifications
1.1 Electrical
Power Requirements
Auto-ranging - 12V to 80V DC ± 25% (9V to 100V DC).
Operating Current
Total system current entering the V+ pin is a function of system volt-
age, LED alert/warning icons, backlight, LCD heater and sender loads.
The table below illustrates the typical and maximum operating current
for a panel with a V+ voltage of 12V with the sender inputs left as
open circuit. The LCD heater circuit typically consumes 310mA when
active. The backlight circuit typically consumes 30mA. For higher
V+ voltages the operating current is reduced accordingly.
enGage™IV Operating Current (mA)
Without Backlight With Backlight With LCD Heater on
V+ Typ. Max Typ. Max Typ. Max
12.0 30 40 60 70 370 380
Operating currents for V+ of 24, 36, 48, 60, 72 and 80 VDC are lower than this listing.
1.2 Mechanical
Size and Weight
Item Enclosed Unit (T) PCB & LCD Module Only (P)
Bezel H x W 120 x 180 mm N / A
Case H x W 91.8 mm x 137.8 mm 82.6 mm x 128.5 mm
Depth 53.5 mm 38.8 mm
Weight 400 g max 200 g max
Display
Dot Matrix LCD (128 X 240 pixels), Backlit
Curtis enGage™ IV Manual
page 1