CLEANING INSTRUCTIONS CI3
GEM SATELLITE, CLEANING INSTRUCTIONS 051420B
Cleaning the Faucet Parts and Site Gauge
10 Wash - Wash the lid and all faucet and gauge
glass parts with the detergent solution. Clean
the inside of the gauge glass with a gauge brush
soaked with detergent solution.
11 Rinse - Thoroughly rinse all parts with clean,
warm water.
12 Sanitize - After rinsing, place the lid and all
faucet and gauge parts in a sink to be sanitized.
Immerse them in One-Pro cleaner mixed at a
ratio of 1 oz. (28 g.) per 5 gal. (19 L) of hot water
(122°F/50°C min.). Allow the parts to soak for 15
minutes.
13 Air Dry - Allow all parts to thoroughly air dry.
14 Reassemble - When dry, reassemble the handle/
bonnet. Hand tighten the handle/bonnet onto the
top of the faucet assembly. Reinstall the site gauge
(if applicable). If replacing a broken gauge glass,
carefully remove any traces of glass from the
silicone parts before inserting the new gauge glass
tube. Reinstall the lid.
WASH
RINSE
SANITIZE