3
ERROR MESSAGE DESCRIPTION CAUSE
(900) 000-0000 EXT (0000)
Water Level ERR.
Fill run error/OverflowThe fill solenoid has either run for
more than 10 minutes on the initial
tank fill or 1 minute, 30 seconds in
normal operation.
Break in the temperature thermistor
circuit.
Open Probe(900) 000-0000 EXT (0000)
Sensor Error
(900) 000-0000 EXT (0000)
Over Temp. Error
Excess Temperature
The sensor is reading the tempera-
ture in the heating tank has risen
above 210ºF.
1-(800)-000-0000
Water Level Error
1-(800)-000-0000
Sensor Error
1-(800)-000-0000
Over Te mp. Error
Error Message
Anerrormessagewillappearonthescreenintheeventofamalfunctionunderthefollowingconditions:
1.WaterLevelOverow.
2.BreakinTemperature
Control Circuit
3.ExcessTemperaturein
HeatingTank
Toturnoffanerrormessage,
press the buttonforve
seconds.
Warmers
Thewarmer,underthebrewconewillturnonautomatically
wheneveracoffeebrewcycleisstarted.Thewarmersmay
beswitchedonandoffusingtheWARMERbuttonsonthe
control panel.
CLEANING
Regularcleaningofyourcoffeebrewerwillmaintainthehighestqualitycoffeeyourequipmentiscapableofproducing.Apropercleaningis
essentialinpreservingtheappearanceofthebrewer.
1. Turnofftheunitatthebuttononthefrontcontrolpanel.
2. Wipeexteriorsurfaceswithadampcloth,removingspillsanddebris.
3. Slidethebrewconeoutandcleanit.Thoroughlysoapthesprayheadareawithamilddetergentsolution.
4. Washthebrewbasket.Useasoftbristledbrushforhardtocleanareas.Washbothpartswithadetergentsolutionorputtheseparts
throughadishwasher.
CAUTION: DO NOT use undiluted bleach or chlorine.
LEFT & RIGHT