DEFINITIONS FOR ILLUMINATED LCD INDICATORS -continued
11. INPUT Meter
This meter measures the A
C voltage that
the UPS system is receiving from the utility
wall outlet. The UPS is designed, through
the use of automa
tic voltage regulation,
to continuously correct output voltage to
connected equipment to a saf
e 110/120
voltage output range. In the event of a
complete power loss, severe planned
power suppression, or over voltage, the
UPS relies on its internal battery to supply
consistent 110/120 output voltage. The
INPUT voltage meter can be used as a
diagnostic tool to identify poor quality
input power.
12. EVENT
This meter records the number of
power outages.
13. MUTE
This icon appears whene
ver the UPS is
in silent mode. The alarm does not beep
during silent mode until the battery reach-
es low capacity.
14. AVR (Automatic Voltage Regulation)
This icon appears whenever your UPS is
automatically correcting low AC line volt-
age without using battery power. This is a
normal, automatic operation of your UPS,
and no action is required on your part.
For more information about functions setup, please refer to the Function Setup Guide.
TROUBLESHOOTING
Problem Possible Cause Solution
Circuit breaker button is
projecting from the back
of the unit.
Circuit breaker has been tripped
due to an overload.
Turn the UPS o and unplug at
least one piece of equipment.
Wait 10 seconds, reset the circuit
breaker by depressing the button,
and then turn the UPS on.
The UPS does not perform
expected runtime.
Battery not fully charged.
Recharge the battery by leaving
the UPS plugged in.
Battery is worn out.
Contact CyberPower Systems
about replacement batteries at:
cyberpowersystems.com/support.
The UPS will not turn on.
The on/o switch is designed
to prevent damage from rapidly
turning it o and on.
Turn the UPS o. Wait 10 seconds
and then turn the UPS on.
The unit is not connected to
an AC outlet.
The unit must be connected to a
110/120V 60Hz outlet.
The battery is worn out.
Contact CyberPower Systems
about replacement batteries at:
cyberpowersystems.com/support.
Mechanical problem.
Contact CyberPower Systems at:
cyberpowersystems.com/support.
PowerPanel® is inactive
(all icons are gray).
The USB cable is not connected.
Connect the USB / serial cable
to the UPS unit and an open USB
/ serial port on the back of the
computer. You must use the cable
that came with the unit.
The USB cable is connected to the
wrong USB port.
Check the back of the computer
for an additional USB / serial port.
Move the cable to this port.
-continued

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CyberPower PFC Sinewave Series and is the answer not in the manual?

CyberPower PFC Sinewave Series Specifications

General IconGeneral
BrandCyberPower
ModelPFC Sinewave Series
CategoryUPS
LanguageEnglish

Related product manuals