Page #30 background imageLoading...
Page #30 background image
CCOOMMPPUUTTEERR SSEETTUUPP 55
This setup allows the CPU to learn a new device or sensor such as the hub,heart rate strap and
optional cadence sensor. NOTE:This process only needs to be used if a new sensor or hub is
being used in conjunction with your CPU or vice versa and if batteries are changed in the hub or
chest strap. There are 2 Learn sequences,1 and 2. Learn 1 is used when you have switched sen-
sors or the CPU and there are no other like bikes with PowerTap SL2.4 within a 30’radius. Learn 2
is used if there are other devices in the area but requires you to remove and reinsert the battery
before activating the Learn 2 sequence.
1) To manually change the hub I.D.Push [Select] to toggle through the
Hub I.D.Press [Mode] to save.
2) In most cases the Hub I.D.will not be known so you can "learn" the I.D.by
pressing [Mode] to advance through the Hub I.D.settings to Learn 1. NOTE:
Learn 1 will search for any active hub so be sure that there are no other
active hubs in the area. If there are,proceed to Learn 2.
3) Learn 1 is initiated by Holding [Select] until "Learn" begins flashing.
When the CPU has learned the device I.D.it will display the I.D.
Press [Mode] to advance to the next device I.D. If it did not learn the device
it will take you back to the most recent Hub I.D. NOTE:Make sure the hub is
"awake" by spinning the wheel or axle.
4) Press [Mode] until Learn 2 is displayed. Learn 2 is used when there are
other "awake" or active PowerTap SL 2.4 hubs within a 30 foot radius.
5) Initiate Learn 2 by first removing the batteries from the hub for 5
seconds and replacing them.Then hold [Select] until "Learn" begins to
flash. When the CPU has learned the hub I.D.it will display the I.D.
Press [Mode] to save and proceed to the next device I.D.If it did not learn
the device it will take you back to the most recent Hub I.D.
30
hub
Id
45847
hub
Id
LEArn
1
hub
Id
LEArn
1
flashing
hub
Id
LEArn
2
hub
Id
LEArn
2
flashing