13
UARTBAUD? Display baud rate setting 1~6
1: 9600bps
2: 14400bps
3: 19200bps
4: 38400bps
5: 57600bps
6: 115200bps
UARTBAUD2 Set output B’s baud rate from 1~6
UARTBAUD4 Set output D’s baud rate from 1~6
UARTBAUD6 Set output H’s baud rate from 1~6
UARTBAUD8 Set output H’s baud rate from 1~6
UARTSW? Display outputs UART status Allowing Matrix to
send commands to Receivers connected device.
UARTSW0 Switch to MCU. Allowing Receivers to
send commands to Matrix.
UARTSW2 Switch to output B and allow Matrix to send com-
mands to Receiver’s connected device.
UARTSW4 Switch to output D and allow Matrix to send com-
mands to Receiver’s connected device.
UARTSW6 Switch to output F and allow Matrix to send com-
mands to Receiver’s connected device.
UARTSW8 Switch to output H and allow Matrix to send com-
mands to Receiver’s connected device.
Quit Exit (for telnet only)
Note: Commands will be not executed unless followed by a carriage
return. All commands are not case-sensitive. Commands are under
RS-232 control only.