EasyManua.ls Logo

D-Link DES-1228/ME - Page 374

D-Link DES-1228/ME
413 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DES-1228/ME Metro Ethernet Managed Switch CLI Reference Guide
370
config bpdu_protection
Purpose
Used to configure trap and log settings for BPDU attack protection events.
Syntax
config bpdu_protection [ trap | log ] [ none | attack_detected | attack_cleared | both ]
Description
Use this command to configure the trap and log state for BPDU attack protection and specify the
type of event sent or logged.
Parameters
none Specifies that events will not be logged or trapped for both cases.
trap Specifies the trap state. The default state is both trap and log.
log Specifies the log state. The default state is both trap and log.
attack_detected Specifies that events will be logged or trapped when a BPDU attack is detected.
attack_cleared Specifies that events will be logged or trapped when the BPDU attack is cleared.
both Specifies that events will be logged or trapped for both cases.
The default setting for log is both and for trap is none.
Restrictions
Only Administrator level, Operator level or Power User level users can issue this command.
Example usage:
To configure the trap state for BPDU attack protection events to send traps for attacks detected and attacks cleared:
DES-1228/ME:5# config bpdu_protection trap both
Commands: config bpdu_protection trap both
Success.
DES-1228/ME:5#