DIGITAL INDICATOR
DN500N
21
CENTRONICS PARALLEL OUT (PRINTER I/F)
SET WEIGHING UNIT PRINT
0 Kg
1 g
F40
2 ton
SELECT DATA OUTPUT IN CASE OF AUTO PRINT
0
Automatic print is operated when weight is less than the setting
value of F80 (near Zero) and increased again to be steady.
F41
1
Automatic print is operated when Steady lamp for weight on scale
is OFF and then ON again.
SET PRINT FORMAT
0
Consecutive Print: Serial and weight will be printed consecutively.
F42
1 Individual Print: Print will be made each time measuring is done.
SET PRINT SUBTOTAL GRAND MEMORY REMOVE
0
Remove Subtotal: Press Clear Key and then press SUB Key.
Remove Grand: Press Clear Key and then press Grand Key
F43
1 Remove Subtotal, Grand automatically once printing is done.
CONTROL PAPER FEEDING ONCE PRINTIN IS COMPLETED
F44
4
0
9
1 Count increase = 1 Line increase
(This will be applied only to individual print and subtotal print.)
SET PRINT LINE INTERVAL
F45
1
0
9
When print output, print 1 line and then adjust the interval to
the next line.
1 Count increase = 1 Line increase
(This will be applied only to consecutive print.)
SUBTOTAL PRINT MODE
0 Output weight value in case of printing subtotal.
F46
1 Print Max. Min and Average value in case of printing subtotal.
SELECT PRINT FONT
0 Korean
F47
1 English