2) DIAGNOSIS OF THE FAILURE
Failure
Cause Diagnosis of Failure Solution
PCB
Status
Error Mode
Can not
heat
water
Overheat
water
Can not
dry
Wiring Disconnectiona
Heater Wash
Disconnection
Connector/Terminal
Seclusion
Heater Wash/Thermistor
Wash Poor
Heater Wash/Thermistor
Wash Poor
Wiring Disconnection
Heater Dry Disconnection
Fuse Temp.
Connector/Terminal
Slipped out
Operation Trouble of FAN
MOTOR
Heater Wash/Thermistor
Wash Failure
Connecting the
disconnecting point
Replacing Heater Wash
Inserting
terminal/connector tightly
Replacing temp. sensor
Replacing temp. sensor
Connecting the
disconnecting point
Replacing Heater Wash
Replacing Fuse Temp.
Inserting terminal/connector
tightly
Replacing Fan Motor
Reassembling the Fan
Replacing temp. sensor
Check whether disconnected or not : See Fig. A
Check whether disconnected or not : if normal, the
resistance between two ends is 23.3~25.7Ω.
Check whether disconnected or not : See Fig. A
Measure the resistance of two ends of the sensor : refer
to the attached temp./resistance table
Measure the resistance of two ends of the sensor : refer
to the attached temp./resistance table
Check whether disconnected or not : See Fig. B
Check whether disconnected or not : if normal, the
resistance between two ends is 22.3~24.7Ω.
Shipped out Check the connection of two ends of fuse
temp.
Check whether disconnected or not : See Fig. B
Excessive Noise : Restraint/Failure of Fan Motor
Fan slipped out : MOTOR is operating, but there is
rotating sound.
Measure the resistance of two ends of the sensor : refer
to the attached temp./resistance table
"H6"
"H6"
"H6"
"H2"
"H2" 또는"H4"
"H7"
"H7"
"H7"
"H7"
"H7" 또는"E3"
"H7"
"H1"
Checking Method of wiring/coil disconnection, connector slipping out on PCB board : Operate with the heater connected
* Inspect Wiring/Heater
Wash Disconnection :
Check the current and
resistance of two
terminals
3P Connector
orange wire
1P Connector
Blue Wire
* Inspect
Wiring/Heater Dry
Disconnection :
Check the current
and resistance of two
terminals
3P Connector
Red Wire
1P Connecor
Blue Wire
[Figure A] [Figure B]