17
Input Control Object Contents Remark
4. Flow Chart of Control of Load Confrontation Mode
Start
End
Initial 240min. passed?
Control Mode?
Avoidance Condition of
Load Confrontatior?
Door Open for more
than 30 seconds?
F-Sensor ON+
5 degree?
Deciding Freezer
Over-load
Deciding Freezer Over Load
Deciding Refrigerator Over Load
Termination of
Frezer Over-load Mode
Termination of
Refrigerator
Over-load Mode
Deciding Refrigerator
Over-load
R-Sensor ON+
5 degree?
Over-load Mode?
Over-load Mode
Control
Normal Mode Control
F Load Con. Time;
20 minutes passed?
F-Sensor OFF Point?
R Load Con. Time;
20 minutes paees?
R-Sensor OFF Rpint?
Y
N
N
N
N
Y
N
Y
Y
Y
Y
Y
Y
Normal Mode Silent Mode
Deciding Fan RPM
Normal Over Load
F Fan 11V 14V
R Fan 11V 14V
C Fan 11V 11V
Deciding Fan RPM
Normal Over Load
F Fan 8V 11V
R Fan 8V 11V
C Fan 8V 8V
N
N
N
N
Y
Y
N