23
1-12. Louver Heater Control
Input Control Object Contents Remark
1. Door Switch
2. COMP
1. Louver
Heater
1. It starts when Door is open while COMP is ON.
2. How to control & Termination
1) ON/OFF with co-working of COMP
2) It stops after Louver Heater Control start, 3 times of COMP OFF.
3. Control Example
1-13. Initial Defrosting
Input Control Object Contents Remark
1. D-Sensor
2. Initial Power
Input
1. Defrosting
Mode
COMP delays
for 6 minutes
at initial
defrosting.
1. Defrosting starts when D-Sensor ≤ 3.5 °C at initial power input.
(It proceeds from PRE-COOL.)
1-14. Explanation after Delivery
Input Control Object Contents Remark
1. FRZ.SET
Button
2. REF.SET
Button
3. Power Cord
1. Electrical
Parts
1. How to start ; Push FRZ.SET Button and REF.SET Button at the same
time for 3 seconds within 10 seconds after initial power input.
2. Electrical Parts are OFF for 3 hours.
3. Display works in normal.
1-15. Prevention of COMP Restart
Input Control Object Contents Remark
1. None
1. COMP 6minutes
Delay
1. COMP does not work until 6 minutes after OFF though F-Sensor is ON.