10.2 Indoor fan does not operate at all (E6).
Connector contact
Motor-related parts
Motor detail check
Operation mode check
PCB assembly check
Check:
Motor driving circuit
Relay output
Check:
Motoroutputconnector
Motorcapacitor
Check:
Motorbearinginserted
state
Fan(Blower)fixedstate
Fan(Blower)contact
state
Replace motor or
PCB assembly