44
Modifying alarm linkage parameter
Table 4-1 Alarm linkage parameter description
You cannot modify the value. Keep it default.
There are two options: NO and NC.
If alarm input type of the alarm device that you purchased is NO, select
NO; otherwise you should select NC.
If fire link is enabled the access controller will output alarms when fire
alarms are triggered. The alarm details will be displayed in the alarm
log.
Alarm output and access link are NO by default if fire link is enabled.
The relay can output alarm information (will be sent to the
management platform) if the Alarm Output is enabled.
The alarm duration, and the range is 1–300 seconds.
You can select an alarm output channel according to the alarming
device that you have installed. Each alarm device can be regarded as
a channel.
After the Access Link is enabled, the access controller will be
normally on or normally closed when there are input alarm signals.
There are two options: NO and NC.
Click OK.
The configuration on the web will be synchronized with the configuration in the client if the
access controller is added to a client.