9
Additional VTH monitors can be added to the system as Extension monitors. These monitors can then be called simultaneously along
with the Master monitor. Up to 9 extension monitors can be added to each master monitor.
To enable this feature and confi gure the additional VTH units;
Login to the VTO web browser and go to Local Setting > Basic and tick the Group Call option.
Click Confi rm to save the setting
On the additional VTH unit, fi rst confi gure the network address within the same range as both the VTO and existing VTH units.
Go to Settings > VTH Confi g and select Master, this will change the VTH to Extension mode. Input the room number of the master unit
followed by #1, as an example if the room number is 1 enter 1#1 or 1#2, 1#3 etc. for further additional units.
Note: When using Extension monitors, the Master monitor room number must have #0 included. For example 1#0
In the Master IP fi eld enter the IP address of the main VTH unit.
The master name must be admin and the master password must be the engineer password of the master monitor.
Select OK to save the setting, the confi guration is now complete.
Adding Extension VTH Units