6 Electrical installation
Installation manual
12
ETVH/X16S18+23EA6V+9W
Daikin Altherma 3 H HT F
4P644728-1 – 2021.02
Item Description
Remote outdoor
sensor
See:
▪ Installation manual of the remote
outdoor sensor
▪ Addendum book for optional
equipment
Wires: 2×0.75mm²
[9.B.1]=1 (External sensor =
Outdoor)
[9.B.2] Ext. amb. sensor offset
[9.B.3] Averaging time
Remote indoor sensor See:
▪ Installation manual of the remote
indoor sensor
▪ Addendum book for optional
equipment
Wires: 2×0.75mm²
[9.B.1]=2 (External sensor = Room)
[1.7] Room sensor offset
Human Comfort
Interface
See:
▪ Installation and operation manual of
the Human Comfort Interface
▪ Addendum book for optional
equipment
Wires: 2×(0.75~1.25mm²)
Maximum length: 500m
[2.9] Control
[1.6] Room sensor offset
WLAN module See:
▪ Installation manual of the WLAN
module
▪ Addendum book for optional
equipment
▪ Installer reference guide
Use the cable delivered with the
WLAN module.
[D] Wireless gateway
WLAN cartridge See:
▪ Installation manual of the WLAN
cartridge
▪ Installer reference guide
[D] Wireless gateway
for room thermostat (wired or wireless):
In case of… See…
Wireless room thermostat ▪ Installation manual of the wireless
room thermostat
▪ Addendum book for optional
equipment
Wired room thermostat
without multi-zoning base
unit
▪ Installation manual of the wired room
thermostat
▪ Addendum book for optional
equipment
In case of… See…
Wired room thermostat
with multi-zoning base unit
▪ Installation manual of the wired room
thermostat (digital or analogue) +
multi-zoning base unit
▪ Addendum book for optional
equipment
▪ In this case:
▪ You need to connect the wired
room thermostat (digital or
analogue) to the multi-zoning base
unit
▪ You need to connect the multi-
zoning base unit to the outdoor unit
▪ For cooling/heating operation, you
also need to implement a relay
(field supply, see addendum book
for optional equipment)
6.3.1 To connect the main power supply
1 Open the following (see "4.2.1To open the indoor unit"[45]):
1 Top panel
2 User interface panel
3 Upper switch box cover
2 Connect the main power supply.
In case of normal kWh rate power supply
Interconnection
cable (=main
power supply)
Wires: (3+GND)×1.5mm²
—