6 Electrical installation
Installation manual
16
ETVH/X16S18+23EA6V+9W
Daikin Altherma 3 H HT F
4P644728-1 – 2021.02
3 Fix the cable with cable ties to the cable tie mountings.
6.3.6 To connect the alarm output
Wires: (2+1)×0.75mm²
Maximum load: 0.3A, 250VAC
[9.D] Alarm output
1 Open the following (see "4.2.1To open the indoor unit"[45]):
1 Top panel
2 User interface panel
3 Upper switch box cover
2 Connect the alarm output cable to the appropriate terminals as
shown in the illustration below.
1+2 Wires connected to the alarm
output
3 Wire between X2M and A4P
A4P Installation of EKRP1HBAA is
required.
a Installation of EKRP1HBAA is required.
b Prewiring between X2M/7+9 and Q1L (=thermal
protector backup heater). Do NOT change.
3 Fix the cable with cable ties to the cable tie mountings.
6.3.7 To connect the space cooling/heating ON/
OFF output
INFORMATION
Cooling is only applicable in case of:
▪ Reversible models
▪ Heating only models + conversion kit (EKHVCONV*)
Wires: (2+1)×0.75mm²
Maximum load: 0.3A, 250VAC
—
1 Open the following (see "4.2.1To open the indoor unit"[45]):
1 Top panel
2 User interface panel
3 Upper switch box cover
2 Connect the space cooling/heating ON/OFF output cable to the
appropriate terminals as shown in the illustration below.