7 Configuration
Installation manual
28
ETVH/X16S18+23EA6V+9W
Daikin Altherma 3 H HT F
4P644728-1 – 2021.02
# Code Description
[2.A] [C–05] External room thermostat type for the
main zone:
1: 1 contact: The used external room
thermostat can only send a thermo
ON/OFF condition. There is no
separation between heating or cooling
demand.
2: 2 contacts: The used external
room thermostat can send a separate
heating/cooling thermo ON/OFF
condition.
7.4.2 Additional zone
Thermostat type
Only applicable in external room thermostat control. For more info
about the functionality, see "7.4.1Main zone"[427].
# Code Description
[3.A] [C–06] External room thermostat type for the
additional zone:
1: 1 contact
2: 2 contacts
7.4.3 Information
Dealer information
The installer can fill in his contact number here.
# Code Description
[8.3] N/A Number that users can call in case of
problems.