EasyManua.ls Logo

Daikin 3MKD58DVM - Defrost Solenoid Valve Removal

Daikin 3MKD58DVM
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removal of Four Way Valve / Defrost Solenoid Valve Si12-793
16 Removal Procedure
6
Disconnect the 2
brazed points, first (e),
and then (f).
Remove the defrost
solenoid valve.
Note:
Do not use a metal saw for
cutting pipes by all means
because the sawdust comes
into the circuit.
When withdrawing the pipes,
be careful not to pinch them
firmly with pliers. The pipes
may get deformed.
Provide a protective sheet or
a steel plate so that the
brazing flame cannot
influence peripheries.
Step
Procedure Points
(f)
(e)
(R12395)

Related product manuals