EasyManuals Logo

Daikin 3MKD75DVM User Manual

Daikin 3MKD75DVM
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
Si12-793 Removal of Distributor
Removal Procedure 17
8. Removal of Distributor
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure Points
Before working, make
sure that the refrigerant
gas is empty in the circuit.
Be sure to apply nitrogen
replacement when
heating up the brazed
part.
Warning
Be careful not to get yourself
burnt with the pipes and other
parts that are heated by the
gas brazing machine.
Warning
If the refrigerant gas leaks
during work, ventilate the
room. (If the refrigerant gas is
exposed to flames, toxic gas
may be generated.)
Caution
From the viewpoint of global
environment protection, do
not discharge the refrigerant
gas in the atmosphere. Make
sure to collect all the
refrigerant gas.
Cautions for restoration
1. Restore the piping by non-
oxidation brazing.
2. It is required to prevent the
carbonization of the oil inside
the four way valve and the
deterioration of the gaskets
affected by heat. (Keep
below 120°C.) For the sake
of this, wrap the four way
valve with wet cloth and
provide water so that the
cloth does not dry.
In case of difficulty with gas
brazing machine
1. Disconnect the brazed part
where is easy to disconnect
and restore.
2. Cut pipes on the main unit
with a tube cutter in order to
make it easy to disconnect.
1
Remove the putty.
2
Heat up and disconnect
the 5 brazed parts to
remove the distributor.
Note:
Do not use a metal saw
for cutting pipes by all
means because the
sawdust comes into the
circuit.
When withdrawing the
pipes, be careful not to
pinch them firmly with
pliers. The pipes may get
deformed.
Provide a protective sheet
or a steel plate so that the
brazing flame cannot
influence peripheries.
Brazed part
Distributor
Putty
Brazed
part
(R2204)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin 3MKD75DVM and is the answer not in the manual?

Daikin 3MKD75DVM Specifications

General IconGeneral
CategoryInverter
Model3MKD75DVM
Cooling Capacity7.5 kW
Heating Capacity8.6 kW
Power Supply220-240 V, 50 Hz
RefrigerantR32
Operating Temperature (Cooling)10 to 46 °C
Operating Temperature (Heating)-15 to 24 °C
Noise Level (Outdoor Unit)49 dB(A)

Related product manuals