Do you have a question about the Daikin 4MKS90EVMA and is the answer not in the manual?
Unfasten the 2 hooks at the bottom first.
Remove the 4 screws on the back and the screw on the left side panel.
Remove the 5 screws.
Remove the 2 screws on the front and the screw on the right side panel.
Remove the 4 screws on the discharge grille.
Remove the screw on the partition plate (2).
Lift up the electrical box and remove it.
Remove the fan motor.
Disconnect the compressor lead wires.
Heat up the brazed part of the discharge side and disconnect the part (a).
Heat up the brazed part of the suction side and disconnect the part (b).
Lift the compressor up to remove it.
| Cooling Capacity | 9.0 kW |
|---|---|
| Heating Capacity | 10.0 kW |
| Refrigerant | R32 |
| Power Source | 220-240 V, 50 Hz |
| Sound Pressure Level (Cooling) | 48 dBA |
| Sound Pressure Level (Heating) | 49 dBA |
| Outdoor Unit Noise Level | 52 dB(A) |
| Indoor Unit Dimensions (HxWxD) | Not applicable |
| Indoor Unit Weight | Not applicable |
| Power Supply | 220-240 V, 50 Hz |