Breadcrumb Field code Setting name Range, step
Default value
Date Value
Installer setting at variance with
default value
Field settings table
9.I [5-02] R/W
0: Disabled
1: Enabled
9.I [5-03] R/W -15~35°C, step: 1°C
0°C
9.I [5-04] R/W 0~20°C, step: 1°C
10°C
9.I [5-05] R/W 0~50 A, step: 1 A
50
A
9.I [5-06] R/W 0~50 A, step: 1 A
50
A
9.I [5-07] R/W 0~50 A, step: 1 A
50
A
9.I [5-08] R/W 0~50 A, step: 1 A
50
A
9.I [5-09] R/W 0~20 kW, step: 0,5 kW
20 kW
9.I [5-0A] R/W 0~20 kW, step: 0,5 kW
20 kW
9.I [5-0B] R/W 0~20 kW, step: 0,5 kW
20 kW
9.I [5-0C] R/W 0~20 kW, step: 0,5 kW
20 kW
9.I [5-0D] R/W (*1)
R/O (*2)
0: 230V, 1~ (*1)
1: 230V, 3~ (*1)
2: 400V
,
3~
(
*2
)
9.I [5-0E]
1
9.I [6-00] R/W 2~40°C, step: 1°C
28°C (*7)
22°C (*8)
20°C
(
*3
)
9.I [6-01] R/W 0~10°C, step: 1°C
2°C
9.I [6-02] R/W 0~10kW, step: 0,2kW
3kW (*3)
0kW
(
*4
)
9.I [6-03] R/W 0~10kW, step: 0,2kW
2kW (*1)
3kW
(
*2
)
9.I [6-04] R/W 0~10kW, step: 0,2kW
4kW (*1)
6kW
(
*2
)
9.I [6-05]
0
9.I [6-06]
0
9.I [6-07] 0
9.I [6-08] R/W
2~20°C, step: 1°C
10°C
9.I [6-09]
0
9.I [6-0A] R/W 30~[6-0E]°C, step: 1°C
60°C
9.I [6-0B] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
9.I [6-0C] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
9.I [6-0D] R/W 0: Reheat only
1: Reheat + sched.
2: Scheduled onl
y
9.I [6-0E] R/W (*3) : 40~75°C, step: 1°C
60°C [E-07]=0
(*3) : 40~80°C, step: 1°C
80°C [E-07]=5
(*4) : 40~60°C, step: 1°C
60
°
C
9.I [7-00] R/W 0~4°C, step: 1°C
0°C
9.I [7-01] R/W 2~40°C, step: 1°C
2°C
9.I [7-02] R/W
0: 1 LWT zone
1: 2 LWT zones
9.I [7-03]
2.5
9.I [7-04]
0
9.I [7-05] R/W
0: Very high
1: High
2: Medium
3: Low
4: Ver
y
low
9.I [8-00] R/O
0~20 min, step 1 min
1 min
9.I [8-01] R/W 5~95 min, step: 5 min
30 min
9.I [8-02] R/W 0~10 hour, step: 0,5 hour
0,5 hour [E-07]=1
3 hour
[
E-07
]
≠1
9.I [8-03] R/W 20~95 min, step: 5 min
50 min
9.I [8-04] R/W 0~95 min, step: 5 min
95 min
9.I [8-05] R/W
0: No
1: Yes
9.I [8-06] R/W 0~10°C, step: 1°C
5°C
9.I [8-07] R/W [9-03]~[9-02], step: 1°C
18°C
9.I [8-08] R/W [9-03]~[9-02], step: 1°C
20°C
9.I [8-09] R/W [9-01]~[9-00], step: 1°C
35°C
9.I [8-0A] R/W [9-01]~[9-00], step: 1°C
33°C
9.I [8-0B]
13
9.I [8-0C]
10
9.I [8-0D]
16
What is the capacity of the backup heater step 2?
Space heating priority temperature.
Set point correction for domestic hot water temperature.
What is the requested limit for DI1?
Space heating priority.
--
The temperature difference determining the heat pump ON temperature.
The temperature difference determining the heat pump OFF temperature.
What is the capacity of the booster heater?
What is the capacity of the backup heater step 1?
What is the requested limit for DI3?
What is the requested limit for DI4?
What is the requested limit for DI1?
--
Backup heater voltage
What is the requested limit for DI2?
What is the requested limit for DI3?
What is the requested limit for DI4?
What is the requested limit for DI2?
What is the hysteresis to be used in reheat mode?
--
--
--
What is the desired comfort storage temperature?
What is the desired eco storage temperature?
What is the desired reheat temperature?
What is the desired DHW production type?
What is the maximum temperature setpoint?
Domestic hot water booster heater overshoot temperature.
Domestic hot water booster heater hysteresis.
How many leaving water temperature zones are there?
--
--
Boiler efficiency
Minimum running time for domestic hot water operation.
Maximum running time for domestic hot water operation.
Anti-recycling time.
Booster heater delay timer.
Additional running time for the maximum running time.
Allow modulation of the LWT to control the room temp?
Leaving water temperature maximum modulation.
What is the desired comfort main LWT in cooling?
What is the desired eco main LWT in cooling?
What is the desired comfort main LWT in heating?
What is the desired eco main LWT in heating?
--
--
--
4P556072-1 - 2018.12 (#) Setting is not applicable for this unit.