Breadcrumb Field code Setting name Range, step
Default value
Date Value
Installer setting at variance with
default value
Field settings table
9.I [9-00] R/W [2-0C]=2:
37~60, step: 1°C
55°C
[2-0C]≠2:
37~55, step: 1°C
55°C
9.I [9-01] R/W 15~37°C, step: 1°C
25°C
9.I [9-02] R/W 18~22°C, step: 1°C
22°C
9.I [9-03] R/W 5~18°C, step: 1°C
8°C
9.I [9-04] R/W 1~4°C, step: 1°C
1°C
9.I [9-05] R/W 15~37°C, step: 1°C
25°C
9.I [9-06] R/W [2-0D]=2:
37~60, step: 1°C
55°C
[2-0D]≠2:
37~55, step: 1°C
55°C
9.I [9-07] R/W 5~18°C, step: 1°C
8°C
9.I [9-08] R/W 18~22°C, step: 1°C
22°C
9.I [9-0C] R/W 1~6°C, step: 0,5°C
1 °C
9.I [9-0D] R/W 0~8, step:1
0 : No limitation
1~4 : 50~80%
5~8 : 50~80% during sampling
6
9.I [9-0E]
6
9.I [C-00] R/W
0: Solar priority
1: Heat
p
um
p
p
riorit
y
9.I [C-01]
0
9.I [C-02] R/W
0: No
1: Bivalent
9.I [C-03] R/W -25~25°C, step: 1°C
0°C
9.I [C-04] R/W 2~10°C, step 1°C
3°C
9.I [C-05] R/W 0: -
1: 1 contact
2: 2 contacts
9.I [C-06] R/W 0: -
1: 1 contact
2: 2 contacts
9.I [C-07] R/W
0: LWT control
1: Ext RT control
2: RT control
9.I [C-08] R/W
0: No
1: Outdoor sensor
2: Room sensor
9.I [C-09] R/W
0: Normally open
1: Normall
y
closed
9.I [C-0A]
0
9.I [D-00] R/W
0: None
1: BSH only
2: BUH only
3: All heaters
9.I [D-01] R/W
0: No
1: Active open
2: Active closed
3: Safet
y
thermostat
9.I [D-02] R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
9.I [D-03] R/W 0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, s
p
an 8°C
9.I [D-04] R/W
0: No
1: Pwr consm
p
ctrl
9.I [D-05] R/W 0: Forced off
1: As normal
9.I [D-07] R/W
0: No
1: Yes
9.I [D-08] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000
p
ulse/kWh
9.I [D-09] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000
p
ulse/kWh
9.I [D-0A]
0
9.I [D-0B]
2
9.I [E-00] R/O
0~5
0: LT s
p
lit
9.I [E-01] R/O
1
9.I [E-02] R/W (*5)
R/O (*6)
0: Reversible (*5)
1: Heatin
g
onl
y
(
*6
)
9.I [E-03] R/O
3: 6V (*1)
4: 9W
(
*2
)
What is the maximum desired LWT for main zone in heating?
What is the mimimum desired LWT for main zone in heating?
What is the maximum desired LWT for main zone in cooling?
What is the mimimum desired LWT for main zone in cooling?
Leaving water temperature overshoot temperature.
What is the mimimum desired LWT for add. zone in heating?
What is the maximum desired LWT for add. zone in heating?
What is the mimimum desired LWT for add. zone in cooling?
What is the maximum desired LWT for add. zone in cooling?
Room temperature hysteresis.
Pump speed limitation
--
Domestic heating water priority.
--
Is an external backup heat source connected?
Bivalent activation temperature.
Bivalent hysteresis temperature.
What is the thermo request contact type for the main zone?
Which heaters are permitted if prefer. kWh rate PS is cut?
Contact type of preferential kWh rate PS installation?
Which type of DHW pump is installed?
Leaving water temperature compensation around 0°C.
What is the thermo request contact type for the add. zone?
What is the unit control method in space operation?
Which type of external sensor is installed?
What is the required alarm output contact type?
--
--
Which type of unit is installed?
Which type of compressor is installed?
Is a demand PCB connected?
Is the pump allowed to run if prefer. kWh rate PS is cut?
Is a solar kit connected?
Is an external kWh meter used for power measurement?
Is an external kWh meter used for power measurement?
--
What is the indoor unit software type?
What is the number of backup heater steps?
(*1) *6V_(*2) *9W_
(*3) *AB*_(*4) EAV*_
(*5) *X*_(*6) *H*_
(*7) EAV*18*_(*8) EAV*23*
(#) Setting is not applicable for this unit. 4P556072-1 - 2018.12