3/10
Breadcrumb Field code Setting name Range, step
Default value
Date Value
Installer setting at variance with
default value
Field settings table
Additional zone
3.7 [2-0D] R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
└─ Setpoint range
3.8.1 [9-05] R/W 15~37°C, step: 1°C
25°C
3.8.2 [9-06] R/W [2-0D]=2:
37~60, step: 1°C
55°C
[2-0D]≠2:
37~55, step: 1°C
55°C
3.8.3 [9-07] R/W 5~18°C, step: 1°C
8°C
3.8.4 [9-08] R/W 18~22°C, step: 1°C
22°C
Additional zone
3.A [C-06] R/W 0: -
1: 1 contact
2: 2 contacts
└─ Delta T
3.B.1 [1-0C] R/W 3~10°C, step: 1°C
5°C
3.B.2 [1-0E] R/W 3~10°C, step: 1°C
5°C
Space heating / cooling
└─ Operation range
4.3.1 [4-02] R/W 14~35°C, step: 1°C
35°C
4.3.2 [F-01] R/W 10~35°C, step: 1°C
20°C
Space heating / cooling
4.4 [7-02] R/W
0: 1 LWT zone
1: 2 LWT zones
4.5 [F-0D] R/W 0: Continuous
1: Sample
2: Re
uest
4.6 [E-02] R/W (*5)
R/O (*6)
0: Reversible (*5)
1: Heatin
4.7 [9-0D] R/W 0~8, step:1
0 : No limitation
1~4 : 50~80%
5~8 : 50~80% during sampling
6
Space heating / cooling
4.9 [F-00] R/W
0: Restricted
1: Allowed
4.A [D-03] R/W 0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
4.B [9-04] R/W 1~4°C, step: 1°C
1°C
4.C [2-06] R/W 0: Disabled
1: Enabled
Tank
5.2 [6-0A] R/W 30~[6-0E]°C, step: 1°C
60°C
5.3 [6-0B] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
5.4 [6-0C] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
5.6 [6-0D] R/W 0: Reheat only
1: Reheat + sched.
2: Scheduled onl
└─ Disinfection
5.7.1 [2-01] R/W 0: No
1: Yes
5.7.2 [2-00] R/W 0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunda
5.7.3 [2-02] R/W 0~23 hour, step: 1 hour
1
5.7.4 [2-03] R/W [E-07]≠
1 :
55~75°C, step: 5°C
70°C
[E-07]=1 : 60°C
60°C
5.7.5 [2-04] R/W [E-07]≠1: 5~60 min, step: 5 min
10 min
[E-07]=1: 40~60 min, step: 5 min
40 min
Tank
5.8 [6-0E] R/W (*3) : 40~75°C, step: 1°C
60°C [E-07]=0
(*3) : 40~80°C, step: 1°C
80°C [E-07]=5
(*4) : 40~60°C, step: 1°C
5.9 [6-00] R/W 2~40°C, step: 1°C
28°C (*7)
22°C (*8)
20°C
5.A [6-08] R/W
2~20°C, step: 1°C
10°C
5.B R/W
0: Fixed
1: Weather de
endent
Operation day
Hysteresis
Duration
Tank setpoint
Hysteresis
Comfort setpoint
Delta T heating
Space heating OFF temp
Pump limitation
Number of zones
Overshoot
Cooling minimum
Cooling maximum
Space cooling OFF temp
Thermostat type
Emitter type
Heating minimum
Heating maximum
Delta T cooling
Maximum
Heat up mode
Reheat setpoint
Eco setpoint
Unit type
Increase around 0°C
Pump operation mode
Antifrost
Start time
Pump outside range
Setpoint mode
Activation
(*1) *6V_(*2) *9W_
(*3) *AB*_(*4) EAV*_
(*5) *X*_(*6) *H*_
(*7) EAV*18*_(*8) EAV*23*
(#) Setting is not applicable for this unit. 4P556072-1 - 2018.12