4 Installation
Installation manual
12
EBLQ+EDLQ011~016CA3V3+W1
Daikin Altherma low temperature monobloc
4P537990-1 – 2018.05
# Action
1 Connect the user interface cable to the outdoor unit.
a Main user interface
(a)
b Optional user interface
2 Insert a screwdriver into the slots underneath the user
interface and carefully separate the faceplate from the
wallplate.
The PCB is mounted in the faceplate of the user interface.
Be careful NOT to damage it.
3 Fix the wallplate of the user interface to the wall.
4 Connect as shown in 4A, 4B, 4C or 4D.
5 Reinstall the faceplate onto the wallplate.
Be careful NOT to pinch the wiring when attaching the
frontplate to the unit.
(a) The main user interface is required for operation, but has to
be ordered separately (mandatory option).
4A From the rear
4B From the left
4C From the top
4D From the top centre
a Notch this part for the wiring to pass through with nippers
etc.
b Secure the wiring to the front part of the casing using the
wiring retainer and clamp.
4.4.5 To connect the shut-off valve
1 Connect the valve control cable to the appropriate terminals as
shown in the illustration below.
NOTICE
Only connect NO (normal open) valves.
INFORMATION
By default, the shut‑off valve is to be connected to the
outdoor unit. However, if control box EKCB07CAV3 is
present in the system, you can also connect it to the
control box. To do this, connect outdoor unit terminals
X3M/1+2 to control box terminals X8M/6+7, and then
connect the shut‑off valve to control box terminals
X8M/6+7.
4.4.6 To connect the domestic hot water pump
1 Connect outdoor unit terminals X3M/3+4 to the bottom side of
terminals X8M/8+9 of control box EKCB07CAV3.
2 Connect the cable of the domestic hot water pump to the
bottom side of control box terminals X8M/8+9.