14 Technical data
Installer reference guide
103
ERLQ004~008CA + EHVH/X04+08S18+26CB
Daikin Altherma – Low temperature split
4P384973-1A – 2016.02
Outdoor units ERLQ004CAV3 ERLQ006CAV3 ERLQ008CAV3
Drain Quantity 2
Type Hole
Diameter (OD) 1ר15mm + 1ר20mm
Piping length Minimum 3m
Maximum 30m
Equivalent —
Chargeless 10m
Additional refrigerant charge 0.02kg/m IF >10m
Maximum height difference between outdoor unit and indoor unit 20m
Defrost method Reverse cycle
Defrost control Sensor for outdoor heat exchanger temperature
Capacity control method Inverter controlled
Electrical specifications
ERLQ004~008CAV3
Power supply
Name V3
Phase 1
Frequency 50Hz
Voltage 230V
Voltage range Minimum –10%
Maximum +10%
Current
Nominal running current Cooling —
Heating
Starting current Cooling 15.7A 15.9A
3
Heating
Maximum running current Cooling 15.7A 15.9A
3
Heating
Z
max
—
Recommended fuses 16A 20A
Wiring connections
For power supply Quantity 3
Remark —
For connection with indoor Quantity 3
Remark No earth wire
Figure A: Starting current
Daikin inverter controlled compressor starting current always less
then or equal to maximal running current.
A Running current
B Time
C Maximum
D Example 1
E Example 2
Standard on/off compressor starting current to maximum running
current
A Running current
B Time
C Maximum
D Example 1
E Example 2
(3)
See figureA.