Loading...
4 About the units and options
Installer reference guide
9
ERLQ004~008CA + EHVH/X04+08S18+26CB
Daikin Altherma – Low temperature split
4P384973-1A – 2016.02
4.2 Identification
NOTICE
When installing or servicing several units at the same time,
make sure NOT to switch the service panels between
different models.
4.2.1 Identification label: Outdoor unit
Location
Model identification
Example: ERLQ006CAV3
Code Explanation
ER European split outdoor pair heat pump
L Low water temperature – ambient zone: −10~
−20°C
Q Refrigerant R410A
006 Capacity class
CA Model series
V3 Power supply
4.2.2 Identification label: Indoor unit
Location
Model identification
Example: EHVH04S18CB3V
Code Description
E European model
HV Floor-standing indoor unit with integrated tank
H H=Heating only
X=Heating/cooling
04 Capacity class
S Integrated tank material: Stainless steel
18 Integrated tank volume
Code Description
CB Model series
3V Backup heater model
4.3 Combining units and options
4.3.1 Possible options for the outdoor unit
Drain pan (EKDP008CA)
The drain pan is required to gather the drain from the outdoor unit.
The drain pan kit consists of:
Drain pan
Installation brackets
For installation instructions, see the installation manual of the drain
pan.
Drain pan heater (EKDPH008CA)
The drain pan heater is required to avoid freezing-up of the drain
pan.
It is recommended to install this option in colder regions with
possible low ambient temperatures or heavy snowfall.
For installation instructions, see the installation manual of the drain
pan heater.
INFORMATION
In case the drain pan heater is used, the jumper JP_DP on
the service PCB on the outdoor unit MUST be cut.
After cutting the jumper, you MUST reset the outdoor unit
to activate this function.
U-beams (EKFT008CA)
The U-beams are installation brackets on which the outdoor unit can
be installed.
It is recommended to install this option in colder regions with
possible low ambient temperatures or heavy snowfall.
For installation instructions, see the installation manual of the
outdoor unit.
4.3.2 Possible options for the indoor unit
User interface (EKRUCBL*)
The user interface and a possible additional user interface are
available as an option.
The additional user interface can be connected:
To have both:
control close to the indoor unit,
room thermostat functionality in the principal space to be
heated.
To have an interface containing other languages.
Following user interfaces are available:
EKRUCBL1 contains following languages: German, French,
Dutch, Italian.
EKRUCBL2 contains following languages: English, Swedish,
Norwegian, Finnish.
EKRUCBL3 contains following languages: English, Spanish,
Greek, Portuguese.
EKRUCBL4 contains following languages: English, Turkish,
Polish, Romanian.
EKRUCBL5 contains following languages: German, Czech,
Slovenian, Slovakian.

Table of Contents