Breadcrumb Field code Setting name Range, step
Default valu
e
Date Value
Field settings table
Installer setting at variance with
default value
A.2.1.5 [5-0D] R/W 0: 1P,(1/2)
1: 1P,(1/1+2)
2: 3P,(1/2)
3: 3P,(1/1+2) (*3)
4: 3PN,(1/2)
5: 3PN
,(
1/1+2
)
(
*4
)
A.2.1.6 [D-01] R/W
0: No
1: Active open
2: Active closed
A.2.1.7 [C-07] R/W
0: LWT control
1: Ext RT control
2: RT control
A.2.1.8 [7-02] R/W
0: 1 LWT zone
1: 2 LWT zones
A.2.1.9 [F-0D] R/W 0: Continuous
1: Sample
2: Re
q
uest
A.2.1.A [E-04] R/O 0: No
1: Yes
A.2.1.B R/W 0: At unit
1: In room
└─ Options
A.2.2.1 [E-05] R/W
0: No (*1)
1: Yes
(
*2
)
A.2.2.3 [E-07] R/W
0~6
0: Type 1 (*1)
1: T
yp
e 2
(
*2
)
A.2.2.4 [C-05] R/W 1: Thermo ON/OFF
2: C/H re
q
ues
t
A.2.2.5 [C-06] R/W 1: Thermo ON/OFF
2: C/H re
q
ues
t
A.2.2.6.1 [C-02] Digital I/O PCB Ext. backup heat src R/W
0: No
1: Bivalent
2: -
3: -
A.2.2.6.2 [D-07] Digital I/O PCB Solar kit R/W
0: No
1: Yes
A.2.2.6.3 [C-09] Digital I/O PCB Alarm output R/W
0: Normally open
1: Normall
y
closed
A.2.2.6.4 [F-04] Digital I/O PCB Bottom plate heater R/W
0: No
1: Yes
A.2.2.7 [D-04] R/W
0: No
1: Pwr consm
p
ctrl
A.2.2.8 [D-08] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000
p
ulse/kWh
A.2.2.9 [D-09] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000
p
ulse/kWh
A.2.2.A [D-02] R/W
0: No
1: Secondary rtrn
2: Disinf. shunt
A.2.2.B [C-08] R/W
0: No
1: Outdoor sensor
2: Room sensor
A.2.2.D [E-0B] Bi-zone kit Is a bi-zone kit installed? R/O
0: No
(
#
)
└─ Capacities
A.2.3.1 [6-02] R/W 0~10kW, step: 0,2kW
0kW
A.2.3.2 [6-03] R/W 0~10kW, step: 0,2kW
3kW
A.2.3.3 [6-04] R/W 0~10kW, step: 0,2kW
0kW (*3)
6kW
(
*4
)
A.2.3.6 [6-07] R/W 0~200W, step: 10W
0W
Space operation
└─ LWT settings
└────────────────── Main
A.3.1.1.1 R/W 0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
A.3.1.1.2.1 [9-01] Temperature range Minimum temp (heating) R/W 15~37°C, step: 1°C
25°C
A.3.1.1.2.2 [9-00] Temperature range Maximum temp (heating) R/W 37~depending on outdoor unit, step: 1°C
55°C
A.3.1.1.2.3 [9-03] Temperature range Minimum temp (cooling) R/W 5~18°C, step: 1°C
5°C
A.3.1.1.2.4 [9-02] Temperature range Maximum temp (cooling) R/W 18~22°C, step: 1°C
22°C
A.3.1.1.5 [8-05] R/W
0: No
1: Yes
A.3.1.1.6.1 [F-0B] Shut-off valve Thermo On/OFF R/W
0: No
1: Yes
A.3.1.1.6.2 [F-0C] Shut-off valve Cooling R/W 0: No
1: Yes
A.3.1.1.7 [9-0B] R/W 0: Quick
1: Slo
w
└────────────────── Additional
A.3.1.2.1 R/W 0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
A.3.1.2.2.1 [9-05] Temperature range Minimum temp (heating) R/W 15~37°C, step: 1°C
25°C
LWT setpoint mode
Modulated LWT
Emitter type
LWT setpoint mode
DHW pump
External sensor
Booster heater
BUH: step 1
BUH: step 2
Bottom plate heater
DHW tank type
Contact type main
Contact type add.
Demand PCB
External kWh meter 1
External kWh meter 2
Unit control method
Number of LWT zones
Pump operation mode
Power saving possible
User interface location
DHW operation
BUH type
Preferential kWh rate
(*1) *HB*_(*2) *HV*_
(*3) *3V_(*4) *9W_
(*5) *04/08*_
(*6) *11/16*
(#) Setting is not applicable for this unit. 4P383508-1 - 2015.01