4 | Operation
User reference guide
24
EHYHBH05AF + EHYHBH/X05+08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355632-1E – 2020.10
T
l
T
r
T
r
: Room temperature
T
l
: Leaving water temperature
3 Press or to adjust/overrule.
To adjust the leaving water temperature (additional)
1 Go to the additional leaving water temperature home page (LWT add).
2 Press or to adjust. Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be modified.
4.4.7 Leaving water temperature control - About leaving water temperature control
Leaving water temperature control means that you only control the leaving water
temperature. To control the leaving water temperature, you can do the following:
You can… Location
Read out the desired leaving water temperature
(main + additional).
Leaving water
temperature home pages
(main + additional)
Adjust/overrule the leaving water temperature
(main).
Adjust the leaving water temperature (additional).
Select which leaving water temperature schedule
(main + additional) you want to use.
Menu structure
Program leaving water temperature schedule (main +
additional).
Define preset values that are used by the leaving
water temperature schedule (main).
See also:
"4.4.6 Room thermostat control - Using the leaving water temperature home
pages"[422]
"4.7Preset values and schedules"[438]