Daikin Altherma EHYHBH05A Series - Leaving Water Temperature Control - Using Leaving Water Temperature Control According to a Schedule; Leaving Water Temperature Control - Using Leaving Water Temperature Control NOT According to a Schedule; External Room Thermostat Control - about External Room Thermostat Control

Daikin Altherma EHYHBH05A Series
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 | Operation
User reference guide
25
EHYHBH05AF + EHYHBH/X05+08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355632-1E – 2020.10
4.4.8 Leaving water temperature control - Using leaving water temperature control according to
a schedule
To set leaving water temperature preset values (main)
INFORMATION
Adjusting the leaving water temperature is permanent unless the leaving water
temperature is according to a schedule. In that case the overruling is valid until the
next scheduled action.
1 Go to [7.4.2]: > User settings > Preset values > LWT main.
2 Press or to adjust. Example:
35°C 37°C
To adjust the leaving water temperature (additional)
1 Go to the additional leaving water temperature home page (LWT add).
2 Press or to adjust. Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be modified.
4.4.9 Leaving water temperature control - Using leaving water temperature control NOT
according to a schedule
To adjust the leaving water temperature (main)
1 Go to the main leaving water temperature home page (LWT main).
2 Press or to adjust. Example:
35°C 37°C
To adjust the leaving water temperature (additional)
1 Go to the additional leaving water temperature home page (LWT add).
2 Press or to adjust. Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be modified.
4.4.10 External room thermostat control - About external room thermostat control
External room thermostat control means that you control the following:
Room temperature on the external thermostat control
Leaving water temperature on the user interface (Daikin)
To control the leaving water temperature, you can do the following: