•Altherma
TM
• Monobloc
107
Monobloc • EDHQ011-016AA6W1
2 Specifications
3
2
2-4 ELECTRICAL SPECIFICATIONS EDHQ011AA6W1 EDHQ014AA6W1 EDHQ016AA6W1
Power supply
compressor
component
Main Power Name W1
Phase 3N~
Frequency Hz 50 50 50
Voltage V 400 400 400
Voltage range Minimum V -10%
Maximum V +10%
Current Nominal running
current (RLA)
Heating (A) A 5.8 5.8 5.8
Maximum running
current
Heating A 14 14 14
Power supply
compressor
component
Current
Recomended
fuses
A20 20 20
Wiring connections For power supply
compressor component
See installation manual
Power supply
hydraulic
component
Current back-up
heater
Type 6W1
Current back-up
heater
Power Supply Phase 3~
Frequency Hz 50 50 50
Voltage V 400 400 400
Running Current Back-up
heater
A 8.7 8.7 8.7
Running Current Back-up heater +
booster heater
+EK*V3 A 21.7(8.7+13)
+EK*Z2 A 16.2(8.7+7.5)
Current back-up
heater
Minimum Ssc value +EK*V3 kVa Equipment complying with EN/IEC 61000-3-12(**)
+EK*Z2 kVa Equipment complying with EN/IEC 61000-3-12(**)