Monobloc • EBHQ011-016AA6W1
2 Specifications
3
2
Expansion vessel Volume l 10 10 10
Maximum water pressure bar 3 3 3
Pre pressure bar 1.0 1.0 1.0
Water filter Diameter perforations mm 1 1 1
Material Brass
Water circuit Piping connections inch G5/4 (FEMALE)
Piping inch 5/4"
Safety valve bar 3 3 3
Manometer Yes
Drain valve / Fill valve yes
Shut off valve yes
Air purge valve yes
Total water volume (6) l 5.5 5.5 5.5
2-4 ELECTRICAL SPECIFICATIONS EBHQ011AA6W1 EBHQ014AA6W1 EBHQ016AA6W1
Power supply
compressor
component
Main Power Name W1
Phase 3N~
Frequency Hz 50 50 50
Voltage V 400 400 400
Voltage range Minimum V -10%
Maximum V +10%
Current Nominal running
current (RLA)
Heating (A) A 5.8 5.8 5.8
Maximum running
current
Heating A 14 14 14
Cooling A 13.5 13.5 13.5
Power supply
compressor
component
Current Recomended
fuses
A20 20 20
Wiring connections For power supply
compressor component
See installation manual
Power supply
hydraulic
component
Current back-up
heater
Type 6W1
Current back-up
heater
Power Supply Phase 3~
Frequency Hz 50 50 50
Voltage V 400 400 400
Running Current Back-up
heater
A8.7 8.7 8.7
Running Current Back-up heater +
booster heater
+EK*V3 A 21.7(8.7+13)
+EK*Z2 A 16.2(8.7+7.5)
Current back-up
heater
Minimum Ssc value +EK*V3 kVa Equipment complying with EN/IEC 61000-3-12(**)
+EK*Z2 kVa Equipment complying with EN/IEC 61000-3-12(**)
2-3 MAIN COMPONENTS EBHQ011AA6W1 EBHQ014AA6W1 EBHQ016AA6W1