2-1 TECHNICAL SPECIFICATIONS EKSOLHWAV1
Dimensions Packing Height mm 795
Width mm 340
Depth mm 295
Unit Height mm 770
Width mm 305
Depth mm 270
Weight Unit kg 8
Packed Unit kg 9
Packing Material Carton
Weight kg 1
Heat
Exchanger
Type Brazed plate
Pressure drop Solar side kPa 21.5
Maximum inlet
temperature
Solar side °C 110
Capacity W/K 1,400
Logarithmic mean
temperature difference
(LMTD)
K5
Pump Type water cooled
Number of speeds 3
Power input W 46
Sound Sound Pressure dBA 27
Water circuit Piping connections
diameter
inch 3/4" FBSP
Insulation material EPP
Ambient
temperature
Maximum °C 35
Minimum °C 1
2-2 ELECTRICAL SPECIFICATIONS EKSOLHWAV1
Unit Power Supply Phase 1~
Frequency
Hz 50
Voltage V 220-240
Voltage range Minimum -10%
Maximum +10%