ESIE09-08A Specifications
Specifications 9
Main
components
AA AB AC AA AB AC AA AB AC
Refrigerant side
heat exchanger
Type Plate heat exchanger Plate heat exchanger Plate heat exchanger
Quantity 1 (60 plates) 1 (60 plates) 1 (60 plates)
Material AISI 316 AISI 316 AISI 316
Insulation material
EPDM
type
Thermal
felt/foam
PPE foam
EPDM
type
Thermal
felt/foam
PPE foam
EPDM
type
Thermal
felt/foam
PPE foam
Cascade
compressor
Quantity 1 1 1
Motor Type Hermetically sealed scroll
compressor
Hermetically sealed scroll
compressor
Hermetically sealed scroll
compressor
Starting Method Direct online Direct online Direct online
Crankcase
Heater
Quan-
tity
1 1 1 1 1
Crankcase
Heater
Output
W
33 33 33 33 33 33
Pump Type DC motor DC motor DC motor
Nr. of speed inverter controlled inverter controlled inverter controlled
Nominal ESP
unit
(1)
Heating kPa
94,0 92 92 91,9 88 88 89,7 85 85
Power input W 87 95 101
Water side Heat
exchanger
Type Plate heat exchanger Plate heat exchanger Plate heat exchanger
Quantity 1 (50 plates) 1 (50 plates) 1 (50 plates)
Material AISI 316 AISI 316 AISI 316
Water volume l 2,78 2,78 2,78
Water flow rate Nom.
(1)
l/min 15,8 20,1 22,9
Water flow rate Max.
(2)
l/min 31,6 40 45,8
Insulation material
EPDM
type
Thermal
felt/foam
PPE
EPDM
type
Thermal
felt/foam PPE
EPDM
type
Thermal
felt/foam PPE
Expansion
vessel
Volume l 12 12 12
Max. water pressure bar 3 3 3
Pre pressure bar 1 1 1
Water filter Diameter perforations mm 1 1 1
Material Brass Brass Brass
Water circuit Piping connections diameter inch G 1”1/4 (female) G 1”1/4 (female) G 1”1/4 (female)
Piping inch 1” 1” 1”
Safety valve bar 3 3 3
Manometer Y/N Y Y Y
Drain valve / Fill valve Y/N Y Y Y
Shut off valve Y/N Y Y Y
Air purge valve Y/N Y Y Y
Heating water system minimum water volume l 20 20 20
Heating water system maximum water volume l 400 400 400
Refrigerant
Circuit
Gas side diameter mm 15,9 15,9 15,9
Liquid side diameter mm 9,52 9,52 9,52
Type Casc. R134a R134a R134a
Charged amount Casc.
Design pressure (high pressure side) bar 38 38 38
Refrigerant oil
Type Casc. Daphne FVC68D Daphne FVC68D Daphne FVC68D
Charged amount Casc. 1,5l 1,5l 1,5l
Sound Level
(3)
Sound Pressure at 55 - 65 °C [EW - LW]
(4)
dBA 43 45 46
Sound Pressure at 70 - 80 °C [EW - LW]
(4)
dBA 46 46 46
Sound Pressure low sound mode n° 1 at 55 - 65
°C [EW - LW]
(4)
dBA
40 43 45
Operation range
(5)
Ambient Minimum °C -20 -20 -20
Maximum °C 20/(35)
(6)
20/(35)
(6)
20/(35)
(6)
Waterside
Minimum LW °C 25 25 25
Maximum LW °C 80 80 80
Installation place Indoor Indoor Indoor
Notes
(1): for ΔT = 10°C
(2): for ΔT = 5°C
(3): The data mentioned is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to environmental
noise and sound reflections. These values are sound pressure levels measured at all sides (front / back / left / right / top) at 1m distance (see engineering data book for more details). The values
do not occur simultaneously on all mentioned sides
(4): EW = entering water temperature - LW = leaving water temperature
(5): for details see operation range TW drawing
(6): for DHW operation
Indoor units EKHBRD011AA/AB/AC(V1/Y1) EKHBRD014AA/AB/AC(V1/Y1) EKHBRD016AA/AB/AC(V1/Y1)