2     3
DR80TC
0603B*
DR80TC
0604B*
DR80TC
0803B*
DR80TC
0804C*
DR80TC
0805C*
DR80TC
0805D*
DR80TC
1005C*

       

       
       
       

       
       
 80 80 80 80 80 80 80
       
       

       
       
Speed       
       
 3 3 5

  10.8   10.8 10.8 10.8
 15 15 15 15 15 15 15
 105 107 110 118 121 129 
¹ Natural Gas BTU/h; for altudes above from 0’ to 4,500’ above sea level, reduce input rang 4% for each 1,000’ above 4,500’ altude. Low-re rate is 70% of
high-re rate.
² DOE AFUE based upon Isolated Combuson System (ICS)
³ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with Naonal Electrical Codes.
Extensive wire runs will require larger wire sizes.
Maximum Overcurrent Protecon Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same
size as noted.

All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
Gas Service Connecon ½” FPT
Important: Size fuses and wires properly and make electrical connecons in accordance with the Naonal Electrical Code and/or all exisng local codes.