EasyManua.ls Logo

Daikin DTA119A71 - Dehumidification Setting

Daikin DTA119A71
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DEHUMIDIFICATION SETTING
The dehumidication performance will be improved by changing the
setting in Daikin
One
+ Smart Thermostat to “A” or “B” or “C”. Accordingly,
the minimum compressor speed will be locked due to different setting.
For example, by selecting “C” the minimum compressor speed will be
xed at 100% dehumidication capability. This operating range limitation
will be unlocked when the humidity reaches the set value.
The default setting is “B”. Please select the proper setting due to your
dehumidication demand or local climate. The setting can be changed
from the dehumidication setting menu at any time when required. For
instance, if “B” is still not adequate, you can select “C” to achieve the
maximum dehumidication performance.
Minimum Maximum
Dehumidication = OFF
A
B
C
Compressor speed
12 English
01-FITQ AOR_DTA119A71_IM_EN.indd 12 2021/02/13 14:20:11