Breadcrumb Field code Setting name Range, step
Default value
Date Value
Field settings table
Installer setting at variance with
default value
9.I [E-04] R/O 0: No
1: Yes
9.I [E-05] R/W (*3)
R/O (*4)
0: No (*3)
1: Yes
(
*4
)
9.I [E-06] R/O 0: No
1: Yes
9.I [E-07] R/W (*3)
R/O (*4)
0~8
0: EKHW, small volume
1: Integrated (*4)
3: EKHW, large volume
5: EKHWP
7: Third party tank, small coil
8: Third party tank, large coil
9.I [E-08] R/W 0: Disabled
1: Enabled
9.I [E-09]
1
9.I [E-0A] R/O (*4)
180 (*10)
230
(
*11
)
9.I [E-0B] R/W
0: Not installed
1: -
2: Bizone kit installed
9.I [E-0C] R/W
0: Without hydraulic separator / no
direct pump
1: With hydraulic separator / no direct
pump
2: With hydraulic separator / with direct
pump
9.I [E-0D] R/O
0: No
1: Yes
9.I [E-0E]
0
9.I [F-00] R/W
0: Disabled
1: Enabled
9.I [F-01] R/W 10~35°C, step: 1°C
20°C
9.I [F-02] 3~10°C, step: 1°C
3°C
9.I [F-03] 2~5°C, step: 1°C
5°C
9.I [F-04]
0
9.I [F-05]
0
9.I [F-06]
0
9.I [F-07]
0
9.I [F-08]
0
9.I [F-09] R/W
0: Disabled
1: Enabled
9.I [F-0A]
0
9.I [F-0B] R/W
0: No
1: Yes
9.I [F-0C] R/W
0: No
1: Yes
9.I [F-0D] R/W 0: Continuous
1: Sample
2: Request
9.I [F-0E] R/W 20
Bizone kit settings
9.P.1 [E-0B] R/W
0: Not installed
1: -
2: Bizone kit installed
9.P.2 [E-0C] R/W
0: Without hydraulic separator / no
direct pump
1: With hydraulic separator / no direct
pump
2: With hydraulic separator / with direct
p
um
p
9.P.3 [7-0A] R/W
20~95%, step 5%
95%
9.P.4 [7-0B] R/W
20~95%, step 5%
95%
9.P.5 [7-0C] R/W
20~300 sec, step 5 sec
125 sec
Is the power saving function available on the outdoor unit?
Can the system prepare domestic hot water?
Is a DHW tank installed in the system?
What kind of DHW tank is installed?
Power saving function for outdoor unit.
--
Is a bizone kit installed?
What bizone system type is installed?
Is glycol present in the system?
--
Pump operation allowed outside range.
--
Close shut-off valve during thermo OFF?
Above which outdoor temperature is cooling allowed?
--
--
--
--
Bizone kit installed
Bizone system type
Close shut-off valve during cooling?
What is the pump operation mode?
--
Pump operation during flow abnormality.
Add zone pump fixed PWM
Main zone pump fixed PWM
Mixing valve turning time
Tank volume
--
--
--
4P655201-1 - 2021.09
(*1) *6V_(*2) *9W_(*3) EBB*_(*4) EBV*_
(*5) *X*_(*6) *H*_(*7) *11*_(*8) *16*_
(*9) *SU*_(*10) *18*_(*11) *23*