9 | Electrical installation
Installer reference guide
77
EWAA011~016DA + EWYA009~016DA
Packaged air-cooled water chillers
and packaged air to water heat pumps
4P620242-1 – 2020.06
demand that the equipment only consumes a limited amount of electricity during
certain periods of time.
The hydro module of the outdoor unit is designed to receive an input signal by
which the unit switches into forced off mode. At that moment, the outdoor unit
compressor will not operate.
The wiring to the unit is different depending on whether the power supply is
interrupted or not.
9.1.5 Overview of electrical connections except external actuators
This topic describes the following power supply layouts:
Normal kWh rate power supply
Preferential kWh rate power supply WITHOUT separate normal kWh rate power
supply
Preferential kWh rate power supply WITH separate normal kWh rate power
supply
Normal kWh rate power supply
dc
A
b
a
b
e
B
5
8
0
1
5
0
0
0
A Outdoor unit
B External backup heater kit
a Electrical cabinet: Normal kWh rate power supply
b Overcurrent fuse
c Compressor module
d Hydro module
e Backup heater
Preferential kWh rate power supply WITHOUT separate normal kWh rate power
supply
During preferential kWh rate power supply activation, power supply is NOT
interrupted. The compressor module of the outdoor unit is turned off by the
control.
Remark: The electricity company must always allow the power consumption of the
hydro module of the outdoor unit.
dc
A
b
a
b
e
B
5
8
0
1
5
0
0
0
S1S
X5M/9+10
A Outdoor unit
B External backup heater kit
a Electrical cabinet: Preferential kWh rate power supply
b Overcurrent fuse